Validation of CFD calculation
The result of CFD calculation is compared with that of spectral
analysis.
The kinetic energy reproduced by the CFD agree well with that by the
spectral
analysis, both of which follow –5/3 power law.
uGS
uSGS
uH
uL
Corresponding to kc = 3